- Suction Strainer - 2" cleanable 30 mesh "Y" type strainer to protect the pump.
- Pump & Motor - 30 gpm gear pump with internal relief valve set at 90 psid. The pump is driven by a 5 hp 460 VAC TEFC electric motor.
- Pump & Motor - 30 gpm gear pump with internal relief valve set at 90 psid. The pump is driven by a 5 hp 460 VAC TEFC electric motor.
- Heater - (optional) The thermostatically regulated 5kW heater increases the temperature of the oil five(5) degrees per pass with a watt density of 16. The heater is sized to raise the oil temperature quickly and to keep the oil flowing during periods of extreme cold.
|
|
- Sample Port - The sample port is equipped with a ball valve and pig tail for ease in taking oil samples. Oil samples taken from this port indicate the oil cleanliness in the lube oil reservoir.
- Differential Pressure Gauges - Pressure gauges are mounted on the filter vessel to indicate when the element needs changing. It is necessary to replace the filter element when the differential pressure reaches 25 psid.
- Control Panel - NEMA 4 rated control panel that contains the on/off switch and 460 VAC. 3-phase, 60 Hz electric connection.
|
|
- Filter#2 - The second filter vessel is a duplicate of the first and uses the Kaydon "Quick-Dry" water removal element.
- Outlet Connection - 1.5" NPT with ball valve for isolation.
- Filter#1 - Particulate filter, equipped with one Kaydon 2.8 micron wire supported dual-phase microfiberglass BETA Absolute particulate removal element. This 6" x 36" filter element is designed for maximum dirt holding capacity with exceptional particulate removal efficiency. The element is protected by an internal bypass valve set at 40 psid. A convenient "Y" top handle is provided for filter element removal and installation. No toolsare required to remove the filter element. The filter vessel is equipped with an air vent and ball valve actuated 1/4" NPT oil drain port.
|